In‐house Cabling process in FTTH : Before this article, I have also written about FTB, FTB means fiber termination point with test facilities between drop cables and inside wiring for customer’s building. The FTB shall be installed in the customer building's outside wall but in this article I will explain about the In house Cabling process in FTTH.
You can also read these important below articles-
Whenever we talk about the cable in the FTTH project, it is often we assume cable upto the customer building walls or we understand that a DP / FTB (distribution Box) install at the wall of customer building and it is the last termination point of cable. But a part of FTTH project is also in-house cabling which has to be completed.
Reference model of In‐house cabling
First of all I talk about the reference model of in-house cabling which will make it easier for all of you to understand. Within the in-house cabling the basic network elements are based on two network structures-
1. direct drop architecture (Point to Point)
2. riser architecture with or without floor distribution boxes.
In-house cabling |
The Interrelation between the BEP and the Floor Distributor and/or the Optical Termination Unit is known as the riser cabling. This is a common network architecture that is used in MDUs.
Riser fiber cables or ducts fed with fibers are usually installed in existing cable conduits e.g. electrical installations or individually installed cable conduits for the FTTH network. This is normal to install a vertical riser from the basement or upper floor of a building.
The vertical riser is the most time consuming installation part of in-house cabling, especially in the section where local fire regulations need to be taken into account as they often pass stairways used as escape routes.
In-house cabling depend on the type of architecture, the number of fibers required for per subscriber and the number of apartments in the building, the riser cables can have various structures: mono fiber, bundles of mono fiber, or bundles of multiple fibers. To understand very easily, you have to look at the image below carefully-
riser architecture |
Since these cables are installed in difficult conditions (eg. low bending radius at the edges) new twist-insensitive fibers should be considered. As the purpose of this article is to clarify the aspects of drop cabling, building entry point, in-house cabling and a optical telecommunications outlet.
In-house cabling the BEP allows the transition from outdoor to indoor cable. The type of transition can be a splice or a removable connection.Building entry point - BEP
Floor distributor - FD
The floor distributor is an optional element that allows the transition from vertical to horizontal indoor cable.In‐house cabling
In-house cabling connects the BEP to the OTO. The main components are an optical indoor cable or similarly, the installation of blowing-based, fiber elements.Optical telecommunications outlet - OTO
OTO is a fixed connecting device where the fiber-optic indoor cable terminates. The optical telecommunications outlet provides an optical interface to the instrument cord of the ONT / CPE.Optical network termination - ONT
The ONT terminates at the subscriber premise and includes an electro-optical converter in the FTTH optical network . The ONT and CPE may be integrated.Customer premises equipment - CPE / SPE
SPE / CPE is a active device at the subscriber end.The subscriber or customer premises equipment is any active device like- set-top box, through these devices FTTH services (high-speed data, TV, telephony, etc.) provided to the subscriber end. The ONT and SPE/CPE may be integrated.Home cabling
Distribution of a wide range of applications, TV, telephone, internet access etc it all provided by the home cabling within the premises. Any specific hardware is not part of the home cabling.User equipment
Subscriber uses the devices as per their convenience and requirement like TV, phone, or personal computer, allows the subscriber to access services.In‐house cabling fiber and cable
Fiber characteristics is also a main important subject in the in-house cabling, BEP is the point at which fibers from the drop cabling and fibers from the in-house cabling have to be connected.
Specifications fibers for the in-house cabling are described in the different standard of the fiber categories and must fulfill certain requirements as-
Outdoor cables- G.652 D, Outdoor cables - G.657 A and Indoor cables - G.657 A.
Bend radius requirements
Bend radius can be consider 30mm and above. For single mode fibers G.652D or G.657A in the BEP and outdoor cable sections bend radius shall be 30mm and above but bending radius in the OTO and indoor cable type for G.657A fibers shall be 15mm and above.Cable type
Optical fiber used for installations at the BEP required optical loose tube fiber cables.Fiber used for installations at the BEP required optical loose tube fiber cables with micro-duct cabling for installation by blowing. Out door cable operating temperature range is between –30°C and +70°C. Out door cable provide 4 fibers between the BEP and each OTO and operating temperature range of indoor cable will be –20°C and +60°C.
As per standard colors, buffered fibers are color coded to differentiate the fibers within the cable. Color coding provide the facility to Installer to easily identify the fiber at both ends. It also indicates the appropriate position of each fiber in the fiber link and cable.
Splice at the BEP
At the BEP fusion splicing is used,there are some special things to keep in mind during fusion splicing on the BEP. Max. attenuation of splices - 0.15 dB , Return loss - > 60 dB and operating temperature range - –25°C to 70°C.Connection box and Splice tray at the BEP
According to the size of building the size of the fiber management system used at BEP. To understand you, I am putting the image of both below so that you can understand easily.Connection box and splice tray used in in-house cabling |
Dear Telecom Friends, are you satisfied with the information given by Technopediasite? I hope you like this article " In‐house Cabling process in FTTH " and your information will be encouraged. If you feel that this information can benefit others, then share it among your friends.
13 Comments
It is not that difficult to contact Xfinity customer service, because it can be simply done by clicking help-center.pissedconsumer.com
ReplyDeleteThank you for your post. This is excellent information. It is amazing and wonderful to visit your site. outdoor optical distribution box
ReplyDeleteHuman Resource Management speculations center around strategies for enlistment and choice and feature the upsides of meetings, general evaluation and psychometric testing as worker choice cycles. домоуправител в софия
ReplyDeleteShockingly, not every person meets the imprint with regards to a perfect house. On the off chance that you need to enlist a cleaning administration to take care of business, do as such. villas in south bangalore
ReplyDeleteNice post, getting FULL Information at one place its really good,, !!! Planet most love music app mp3 juice get here thanks ....
ReplyDeleteNice post, getting FULL Information at one place its really good,, !!! World most Famous app to make life easier without any problems thanks ....
Generally the main piece of picking flooring for your home is the style, the second might be the spending plan. agree with
ReplyDeleteThe twelfth house spans (adjusts) the genuine attention to self quadrant as it experiences the emotional familiarity with self or instinct quadrant started by the first house. Thought gives way to instinct. Europa-Road túlméretes szállítás
ReplyDelete
ReplyDeleteThe top portion of the wheel addresses the time from day break to sunset, the externalized, participatory, outgoing self. професионален домоуправител цени
Thank you so much as you have been willing to share information with us. We will forever admire all you have done here because you have made my work as easy as ABC. fiber optic cable installation contractors
ReplyDeleteassuming they are going to 12-Step gatherings, directing meetings (whenever offered), and whatever other issues that might have come up during their visit. Most great asylums expect inhabitants to go to one or the other or both inside and off grounds 12-Step Meetings (Typically 12-Step participation is at least 1 every day at first, and no less than 3 gatherings each week as a support level- Qld Waterproofers
ReplyDeleteDuring this post, you have shared fantastic content. This article provided me with some useful knowledge. Thank you for sharing Network Design Services Houston. Keep up the good work.
ReplyDeleteThe midheaven is the point that starts the outer, personal responsibility three houses of thought (10, 11, 12).kitchen renovations knysna
ReplyDeleteThank you for sharing this wonderful article!
ReplyDelete